Multi Circuit Power Monitoring System

Home > Multi Circuit Power Monit...

EngyBrick - Multi Circuit Power Metering and Monitoring System

EngyBrick multi circuit power metering and monitoring system provides a flexible and cost effective solution for mid-large power system to improve energy efficiency.
  • EngyBrick in Energy Management Soluton V1.3Download
  • EngyBrick System Instruction - AC V1.5Download
  • EngyBrick System Instruction - DC V1.5Download
Request Quote
Description Product features Connection Main Specifcations

Overview
The EngyBrick multi circuit power monitoring solution is an innovative power monitoring solution that has revolutionized power metering. Based on the concept of modular design, the solution introduces a design idea based on voltage centralized measurement and load loop current separated measurement. It divides the functions of voltage, current collection and display access into individual modules, which greatly increases the flexibility of the system and reduces the cost. Additionally, this distributed metering system also has the advantages of simple installation, flexible deployment and easy accessibility.

Applications
Office Application
application in distribution box
engybrick applied in moitoring office area
Distribution Board Retrofitting Application

application in DBEngybrick for retrofitting DB












application in DBapplication in distribution board

01

Flexibility

  • Brick and modular design allows the metering system to be expanded easily
  • Compatible with AC/DC power systems, widely applied in factories, renewable power, microgrids, data centers, buildings and infrastructure.  

02

Innovation

  • Convenient RJ45 interconnection of modules(EngyBus).
  • Easy RJ12 current sensor connection.
  • Unique Class 0.5 system accuracy and power quality analyzing
  • Automatically identify our dedicated various CTs

03

Implement

  • Din rail design eliminates the need for screws
  • Modules RJ45 interconnection and RJ12 CT connection simplify the installation and expanding operation

04

Monitoring parameter

  • ULL, ULN, I, P, Q, S, PF, import Energy, export Energy
  • THD U&I, Harmonics
  • limited alarm, SOE recording, multi tariffs

05

Data accessing

  • Equipped with a widely used RS485 interface, the system interface can be integrated into BMS, SCADA, PV, and EV systems with few efforts 
  • Providing wireless wifi data accessing version

06

UL Certified

  • All modules passed the relevant UL tests to ensure the safety and accuracy of the system 
  • Both certified version, non-certified version are available

Basic System Connection
AC Power System
AC power system measuring
DC Power System
DC power system measuring


Multi Circuit Plug & Play Connection

  • Fast & Convenient RJ45 interconnection of modules(EngyBus)
    Fast RJ45 modules interconnection
  • Easy RJ12 current sensor connection
CT connection

Whole system(DC+AC)

AC/DC mixed power monitoring
Details of AC monitoring system
details of the AC monitoring solution


Main Specifications

Energy and power measurement

Active energy and active power accuracy

Individual module: class 0.2, solid core CTs: class 0.5, split core CTs: class 1

Reactive energy accuracy

Class 2

Power factor measurement

Accuracy

Solid core CTs: class 0.5, split core CTs: class 1

Voltage measurement of EngyBrick EBU 10

Measuring range

48-480VAC(ph/N)

Frequency

45-65Hz

Frequency accuracy

±0.02Hz

Monitoring Type

1P2W/3P3W/3P4W

Voltage measurement accuracy

Class 0.2

Power consumption

0.4W to 0.5W

Connection

Removable screw terminal block, 4-core, 0.2-2.5mm² cable

Current measurement of EngyBrick EBI10

Number of accesses

3

Related transformer

EBT20

Current measurement accuracy

Individual module: class 0.2, solid core CTs, split core CTs: class 0.5,

Connection

RJ12 interface, 6-core custom cable

Power consumption

0.4W to 0.5W

Q & A  

1. What type of CTs do you recommend using?
EngyBrick can be connected to three different types of CTs: solid-core, split-core, and flexible. You can choose the appropriate transformer based on the project environment and rated current. The split-core CTs can ensure uninterrupted power during the project construction process.

2. Is the installation and debugging process complicated?
The modules are designed with a rail-type installation and do not require screws for installation. The module connections are made through wired connections, making the wiring process simple and easy. The current modules can automatically recognize and connect to CTs (CTs) for automatic network configuration. This feature simplifies the entire installation and debugging process, saving time and effort compared to conventional monitoring instruments that require manual configuration.

3. Can it be used for single-phase loads?
The current modules can measure single-phase, two-phase, and three-phase loads simultaneously.

4. Which scenarios is it suitable for?
It is suitable for scenarios with numerous measurement points and energy monitoring requirements including factories, buildings, photovoltaic power generation, microgrids, and infrastructure.