Multi function Power Meter

Home > Multi function Power Mete...

Multi tariffs high accuracy DC power meter for solar power

DJSF82 DC electric energy meter is a rail-mounted intelligent meter designed for the power statistics and management needs of power systems, industrial and mining enterprises, public utilities, telecom base stations, DC charging piles, solar photovoltaic.
Request Quote
Description Product Feartures Main Specifications Ordering Guide
Products Description

DJSF82 DC electric energy meter is a UL certified rail-mounted intelligent meter designed for the power statistics and management needs of power systems, industrial and mining enterprises, public utilities, telecom base stations, DC charging piles, solar photovoltaic. The product has the advantages of high precision, small size and easy installation. The meter could measure voltage, current, power, and forward and reverse energy of dual DC circuits in a DC system. The instrument can be widely used in various control systems, power monitoring systems and energy management systems, and can be easily collected and remotely controlled through supporting background management software or other industrial configuration software.

The instrument has RS-485 communication interface, supports Modbus-RTU protocol and DLT645-2007 protocol, and can be equipped with relay alarm output and switching input function. According to different requirements, the rated current, alarm and communication are set through the buttons on the instrument panel.

Main Features

Instantaneous true RMS value

Current, voltage, active power

Maximum/minimum value

Max/Min current, voltage, active power

Demand and peak demand value

Current, active power

Energy

Input/output active reactive energy, month-end electrical energy

Multi-tariffs

8 billing periods, 4 tariffs can be set

Alarm

8 configurable limit alarm channels & 4 configurable logical alarm channels

Communication

RS-485 /MODBUS-RTU, DL/T 645-2007

Display

TFT LCD

Real-time clock

Year, month, day, minute, second

Other

Program online upgrade supported

Optional Features

Dual circuits monitoring

1 circuit or 2 circuits

Digital Output (DO)

2 DO, 2A/30VDC or 2A/250VAC(optional) 

Digital Input (DI)

2 dry contact inputs or 2 channels of Hall sensor power supply (optional)

Electrical characteristics

System

DC system (1 circuit / 2 circuits)

Measurement accuracy

Active energy

Class 1.0

Voltage input

Rated voltage(6 options)

DC100V, DC300V, DC500V, DC700V, DC750V, DC1000V

Current input

Measuring current(7 options)

Shunt5A~1000A/75mV, Hall sensor5A~3000A /0-20mA4-20mA0-4V0-5V0-10V0-100mA

Hall Sensor Power Supply

Supply voltage

±12V(±10%) or 24V(±10%) 

Power supply

≤ 1W

Working power supply(three options)

AC

85~265 VAC/45-65Hz

DC

9~36 VDC

Power consumption

≤ 5W

Function

Display

Screen

TFT LCD

Resolution

240*320

Communication

Interface

RS485

Protocol

Modbus-RTU, DL/T 645-2007

Baud rate

2400, 4800, 9600, 19200, 38400, 57600

Switching IO

Output

2 DO, 2A/30VDC or 2A/250VAC(optional) 

Input

2 dry contact inputs or 2 channels of Hall sensor power supply (optional)

Pulse output

PPS output

Default to PPS output

Energy pulse output

It needs to be set according to the power level

Hall Sensor Power Supply

Supply voltage

±12V(±10%) or 24V(±10%)

Power supply

≤ 1W

Mechanical characteristic

Weight

≤0.5kg

Size

93mm*72mm*71.4mm

Operating temperature

-20~70°C

Storage temperature

-25~70°C

Humidity

≤93%RH, non-condensing, no corrosive gases

Altitude

≤2500m

Code: DJSF82-A-B-C-D-E-F-G-H

A. Model code: Rated voltage

1

DC1000V

2

DC750V

3

DC700V

4

DC500V

5

DC300V

6

DC100V

B. Model code: Type of current sensor

1

Shunt: 75mV

2

Hall sensor: 0-5V

3

Hall sensor: 0-4V

4

Hall sensor: 0-20mA

5

Hall sensor: 4-20mA

6

Hall sensor: 0-100mA

7

Hall sensor: 0-10V

C. Model code: Working power supply

1

85-264 VAC/45-65Hz, 100-300 VDC

2

9-36 VDC

D. Model code: Number of measured circuits 

1

1 channel

2

2 channels

E. Model code: Digital Output (DO)

0

No DO

1

1 DO

2

2 DOs

F. Model code: Digital Input (DI)

0

No DI, no hall sensor power supply
1

2 DIs

2

The second hall sensor power supply

3

1 DI

G. Model code: The first hall sensor power supply
0

No hall sensor power supply

1

The first hall sensor power supply

H. Model code: Number of RS485 communication channel
1

1 channel

2

2 channels