Power Meter and Energy Monitor

Home > Power Meter and Energy Mo...

PMC180N-S 3 Phase Digital Power Meter

Item No.: 00008
The PMC180N-S Three-phase Digital Power Meter is designed with no display panel, which is economical and has complete functions, and can be applied to various power scenarios.
Add to Inquiry
Description Technical Parameters Installation wiring Order information
1. Product Features

  a. Full power parameter measurement, electric energy measurement, up to 31 times voltage and current harmonic analysis;
  b. Phase sequence monitoring, phase angle difference, sequence component, unbalance, load properties and other parameters measurement;
  c. Measurement of current K coefficient, voltage crest coefficient ( CF ) and other parameters;
  d. Online monitoring of electrical parameter over-limit alarm;
  e. No display network table, the transmitter output can be configured;
  f. Support MODBUS-RTU standard protocol, RS485 communication;
  g. The product can be connected with an open current transformer to realize the construction and transformation of uninterrupted power supply.
2. Product overview

      The PMC180N-S Three-phase Digital Power Meter is a multi-function power parameter measuring instrument without display operation panel, which can replace a variety of instruments, transformers and other components, and can be installed in different positions in the power distribution system.

      The instrument has RS-485 communication interface, optional wireless communication module, can be integrated into a variety of power monitoring systems, and data collection can be conveniently carried out through the supporting management software or other industrial configuration software.

      This instrument is a true rms-based measuring instrument that can accurately measure highly nonlinear loads. Advanced grid frequency synchronous sampling technology enables it to accurately measure a variety of power parameters, including voltage / current rms, frequency, active power, reactive power, apparent power, power factor, input / output active energy, total active energy, Input / output reactive power, total reactive power, apparent power, voltage total harmonic distortion (THD) , 1~31 voltage harmonics, current total harmonic distortion (THD) and 1~31 current harmonics, etc. . All measurements, maximum and minimum values, and demand measurements can be viewed remotely using the software.

3、 Application scenarios

             a.Industrial distribution automation system          b.Energy efficiency management system
             c.Substation automation system                            d. Electrical engineering of intelligent building
             e.Power plant auxiliary power system                     f.High and low voltage switchgear

Electrical Characteristics

Measure Type
3P3W ACsystem,3P4W ACsystem

Sampling Rate

128 points per cycle

Data refresh rate

1S

Measure accuracy

Current

± 0.2%FS

Voltage

± 0.2%FS

Power

0.5S

Frequency

± 0.001Hz

Active energy

0.5S

Reactive energy

1.0S

DC input (AI)

0.5% FS

DC output (AO)

0.5% FS

Input Voltage Characteristics

Measure

Voltage

3 *220/380V ( direct access )

3 * 57.7/100V (PT secondary side )

Allowed overload capability

1.2 times / continuous

input resistance

300K Ω / phase

Input current characteristics

measure current

5A (CT Secondary side)Or 1A (CT Secondary side)

Allowed Overload

capability

1.2 times / continuous

input resistance

< 0.1Ω

Switch input

Working valtage

15VDC

input resistance

12KΩ

isolation voltage

2KV

4-20mA DC input measurement

measure current

4-20mA

Allowed Overload

capability

1.2 times / continuous

input resistance

10Ω

isolation voltage

2KV

0-5V DC input measurement

Measure

voltage

0-5V

Allowed Overload

capability

1.2 times / continuous

input resistance

12.5KΩ

isolation voltage

2KV

4-20mA DC output

Open-circuit

15VDC

load capacity

600Ω

isolation voltage

2KV

Power supply

AC AC

85~264VAC/45-65Hz

DC

100~375VDC

Power consumption

< 3W

Mechanical performance

weight

0.5kg

IP protection class

Meter Host IP30
Dimension

host

110 X 80 X 75mm

Operating temperature

meter

-25~ 70

storage temperature

meter

-40~ 85

Relative humidity

5% - 90%RH , no condensation

EMC

Anti-static discharge interference

IEC 6 1000-4-2 ,Level 4

Immunity to fast transient bursts

IEC 6 1000-4-4 ,Level 4

Anti-surge

IEC 6 1000-4-5 ,Level 3

Anti-power frequency magnetic field

IEC 6 1000-4-8 ,Level 3

Installation

PMC180N 3-phase digital power meter (no indicator) use 35mm DIN rail  mounting or use M4 screws.

Fig. (1) Frame size (Unit:mm) 

System wiring connection patterns

    The power parameter meter can measure directly when the voltage less than or equal to 264V (phase) / 456V (line) and does not need to connect an external PT, otherwise it need to connect via an external PT. The power parameter meter support a variety wiring of measurement modes and as following use the graph of the method (Fig. 2..... Fig.7) to process explanation separately.

                                   
         
      Fig. (2) 3 phase/4 line wiring system,No PT,3CT         Fig. (3) 3 phase/4 line wiring system,3PT,3CT
                            
              Fig. (4)  3 phase/3 line wiring system,No PT,3CT           Fig. (5) 3 phase/3 line wiring system,No PT,2CT

                              
                  
Fig. (6) 3 phase/3 line wiring system,2PT,3CT              Fig. (7) 3 phase/3 line wiring system,2PT,2CT 

 

Note: The fuse in the above diagrams is recommended at the rated current 250 mA.                                   

Model Specifications: PMC180N-S----

① Model code:

1

57.7/100V rated measuring voltage, 5A Rated measuring current.

2

57.7/100V rated measuring voltage, 1A Rated measuring current.

3

220/380V rated measuring voltage, 5A Rated measuring current.

4

220/380V rated measuring voltage, 1A Rated measuring current.

5

57.7/100V rated measuring voltage, external current transformer.

6

220/380V rated measuring voltage, external current transformer.

②Model code:

1

Working power: 85~264 VAC/45-65Hz , 100~300 VDC .

③'s model code:

0

No DI

1

1 way DI

④ Model code:

0

none

1

0-5V DC analog input measurement (AI)

2

4-20mA DC analog input measurement (AI)

3

03   - 4-20mA DC analog output (AO)

* Note: DI and AI/AO ports are multiplexed. If DI is selected, AI/AO cannot be selected; if AI/AO is selected for A1 port, DI cannot be selected.

Example: The ordering model is: PMC180N-S-3-1-1-0
That is, PMC180N-S is rated to measure 220/380V , 5A ; the working power is 85~264 VAC/45-65Hz ; it is equipped with 1 switch input (DI) ; there is no AI/AO .